[1] ITI consensus statement · 2018
Accuracy of Static Computer-Aided Implant Surgery (new tab)Tahmaseb A, Wismeijer D, Evans C; 6th ITI Consensus Conference. ITI Consensus Database. Digital Technologies, ITI CC 2018.
Full consensus verified. Clinical Recommendations 1–7 describe static guidance as an additional tool, require prosthetically driven planning, support surface-scan/DICOM alignment and emphasize training and hardware calibration according to manufacturer guidance. Recommendation 4 specifically advises a 2 mm margin from critical anatomical structures for s-CAIS. This published recommendation must be acknowledged in its implant-surgery context; it is not a software clearance certificate, a maximum possible error or a guarantee against injury. It cannot be transferred unchanged to every instrument, sinus window or corticotomy. The consensus and reference 2 share an evidence base and are not independent replications.
[2] Systematic review and meta-analysis · 2018
The accuracy of static computer-aided implant surgery: A systematic review and meta-analysis (new tab)Tahmaseb A, Wu V, Wismeijer D, Coucke W, Evans C. Clinical Oral Implants Research. 29(Suppl. 16):416–435. doi:10.1111/clr.13346.
Full text verified. Twenty heterogeneous clinical studies included 2,238 implants in 471 patients; only one was randomized. Static guides transferred a predetermined plan with residual deviations, rather than guaranteeing its reproduction. Discussion sections on cumulative workflow error, guide seating, mucosal swelling and instability support checking data correspondence and clinical fit separately. Few studies evaluated realization of the intended prosthetic plan or final aesthetics. Pooled placement accuracy therefore does not establish better long-term outcomes, validate an individual guide or supply a patient-specific acceptance threshold. This review concerns static implant guidance, not sinus-membrane elevation or orthodontic expansion.
[3] EFP S3 clinical practice guideline · 2023
Prevention and treatment of peri-implant diseases—The EFP S3 level clinical practice guideline (new tab)Herrera D, Berglundh T, Schwarz F, et al.; EFP workshop participants and methodological consultant. Journal of Clinical Periodontology. 50(Suppl. 26):4–76. doi:10.1111/jcpe.13823.
Full text verified. Recommendations R5.1–R5.3 connect implant planning with risk-factor management, periodontal stability, prosthetically guided three-dimensional positioning and access for patient cleaning and professional monitoring. R5.6 recommends regular supportive peri-implant care. R5.2 is an expert-based recommendation with low-quality evidence; the background to R5.3 also identifies indirect evidence and expert consensus. These recommendations explain why a technically transferred implant position still needs biological and restorative review. They do not establish that a guide prevents peri-implant disease, and they provide no universal numerical bone, spacing or emergence-angle rule for this teaching exercise.
[4] Randomized clinical trial · 2025
Patient-Reported Healing of Static Computer-Assisted Sinus Lateral Window Osteotomy: A Randomized Controlled Trial (new tab)Narongchai N, Arunjaroensuk S, Subbalekha K, Kamolratanakul P, Pimkhaokham A, Mattheos N. Clinical Implant Dentistry and Related Research. 27(3):e70057. doi:10.1111/cid.70057. PMID:40448540.
Full text verified through the official NCBI BioC full-text service after intermittent PMC/Wiley browser access failures. Forty patients were randomized, twenty per group. The supported guide was fit-tested and used to define the lateral window; Figure 2c shows removal after marking. Membrane elevation remained a separate surgical step. Guided window preparation and total surgery were faster, but healing and most patient-reported measures were not better; three membrane perforations occurred in each group. Patients with sinus pathology requiring management were excluded. This small trial does not establish prevention of perforation, validate management of diseased sinuses or prove that a window guide controls membrane elevation.
[5] Selected clinical package randomized trial · 2023
The efficacy and accuracy of 3D-guided orthodontic piezocision: a randomized controlled trial (new tab)Gibreal O, Al-Modallal Y, Mahmoud G, Gibreal A. BMC Oral Health. 23:181. doi:10.1186/s12903-023-02902-6. PMID:36978052.
Full text verified. Thirty-two selected adults with severe maxillary anterior crowding were randomized sixteen per arm. Guided piezocision plus extraction-based orthodontics was compared with conventional orthodontics, without a freehand-piezocision arm. Follow-up ended at the defined anterior leveling/alignment endpoint. The study cannot isolate the contribution of guidance, predict whole-treatment duration, establish prevention of uncommon root injury or validate skeletal expansion. Its published dimensions and proposed clearance belong to that protocol and are not instructions for another patient or guide. A small reported mean deviation is not a clinical safety threshold.
[6] Single-case technique report · 2025
Digitally guided corticotomy using a customized surgical template (Suya corticotomy utility template): A technique report (new tab)Tsukiboshi Y, Choi J, Fukumoto T, Nakajima R. Clinical Advances in Periodontics. First published online 21 August 2025; 2026;16(2):428–434. doi:10.1002/cap.70009.
Full text verified. This report describes a custom template directing planned corticotomy paths in one maxillary anterior-retraction case. The Discussion explicitly states that this guide does not control osteotomy depth and that tactile feedback remains necessary; broader clinical validation is required. This is direct evidence that a visible guided path and mechanical depth control are different design properties. It does not establish comparative safety, a universal cutting depth, a root-clearance rule or skeletal-expansion success. Its reported postoperative observation cannot certify safety for a different patient or template.
[7] EFP S3 clinical practice guideline · 2022
Treatment of stage IV periodontitis: The EFP S3 level clinical practice guideline (new tab)Herrera D, Sanz M, Kebschull M, et al.; EFP Workshop Participants and Methodological Consultant. Journal of Clinical Periodontology. 49(Suppl. 24):4–71. doi:10.1111/jcpe.13639.
Full text verified. For the specific population with successfully treated stage IV periodontitis, R7.2 places orthodontic treatment after periodontal treatment endpoints are reached. R7.7 requires periodontal monitoring during treatment and interruption of active movement if periodontitis recurs; R7.8 addresses retention and continuing support. These are interdisciplinary care principles, not validation of guided corticotomy or expansion. Their patient-population boundary should remain explicit; the chapter must not infer that a pictured patient has stage IV periodontitis or that guide manufacture establishes periodontal readiness.