Skip to content
Digital planning learning map

OsteoPerio Academy / Digital planning / Chapter 01

Digital records.
A clinical question before a virtual plan.

Understand what each dataset contributes, how the records relate to one another and what needs checking before implant planning begins.

Follow the records pathway

For qualified dentists and postgraduate clinicians · Clinical review pending. This chapter explains planning concepts; practical application requires clinical assessment and appropriate training.

Different datasets, one reviewed planning sceneConceptual data map. A clinical question frames three contributions: a radiographic volume, an optical surface and a restorative proposal. Arrows connect the datasets to a shared planning scene that still needs review against the patient’s clinical findings. The symbols are data objects, not anatomical or diagnostic images.Clinical question + examination + patient goalsRadiographic volumeCBCT / DICOMOptical surfaceVisible geometryRestorative proposalIntended teethShared coordinates. Distinct information.Register and inspect the datasets, then review them clinically.File collection and a combined display do not complete the diagnosis.ORIGINAL CONCEPT MAP · DATA RELATIONSHIPS, NOT ANATOMY OR MEASUREMENTS
Different records answer different questions. This original map explains their relationship; it is not a scanner prescription, a registration result or a clinical acceptance test.

01 / Define the problem

Begin with the person and the treatment objective.

History and clinical findings give the digital records their purpose. The 2026 imaging recommendations place examination and review of previous images before selection of additional radiography. Digital tools support a comprehensive diagnosis and plan.[1][2]

  1. 01

    What are we treating?

    Describe the diagnosis, symptoms, relevant findings and the patient’s priorities.

  2. 02

    What are we proposing?

    State the restorative objective and the alternatives still under discussion.

  3. 03

    What information is missing?

    Identify the question that each additional record needs to answer.

OsteoPerio discussion prompts. File collection does not replace the clinical record.

02 / Complementary information

Know what you are looking at.

Clinical record

History, examination, periodontal and restorative findings, symptoms and goals.[1][2]

What is the diagnosis, and what problem are we trying to solve?

Radiographic volume

CBCT data, commonly exchanged as DICOM, add three-dimensional radiographic information.[1][4]

Which anatomical question does the indicated examination answer?

Optical surface

An intraoral scan records visible surfaces; a scanned cast is another source of surface geometry.[3][4]

Are the relevant surfaces captured clearly and completely?

Photographs & restorative records

Clinical photographs, occlusal records and the restorative proposal provide context for the intended teeth.[2]

Do the proposed restoration and clinical findings agree?

03 / Imaging selection & limitations

Choose imaging for the clinical question.

The ADA/AAOMR recommendations emphasize patient-specific selection, existing diagnostic information and judicious CBCT use. Assess whether the available images answer the clinical question before requesting more. Acquisition parameters and interpretation belong to the appropriate clinical and radiological workflow.[1]

Record image limitations rather than treating a detailed rendering as complete information. Metal artefacts and poorly represented reference surfaces can also affect subsequent registration.[7]

04 / Registration & review

Bring the datasets together. Inspect the correspondence.

Registration aligns shared reference information. Flügge’s study examined intraoral scans; Han’s clinical study used optically scanned casts. Keep the acquisition method and the question studied distinct.[4][7]

Existing OsteoPerio planning image showing a three-dimensional jaw reconstruction and coloured segmented teeth, before the white optical surface overlay.

01 / Jaw reconstruction

The existing planning view shows a reconstructed jaw and segmented teeth. A surface rendering is one view of the source information.

The same existing jaw-planning view with a white optical surface model superimposed over the reconstructed teeth and jaw.

02 / Surface overlay

The white surface model is displayed with the reconstruction. This screenshot illustrates the relationship; it does not establish that registration is accurate.

A local match does not establish agreement elsewhereTwo regions of one invented registration are compared. In region A the solid blue and dashed gold reference outlines nearly coincide. In region B the gold outline is displaced and tilted relative to the blue outline. This demonstrates why more than one region must be inspected; these are abstract contours, not teeth, patient data, measured errors or acceptance thresholds.Inspect the match beyond one favourable view.Dataset ADataset BRegion ARegion BLocally similar contoursOne region of the same matchDisagreement elsewhereA reason to investigate furtherCheck distributed regions and relevant sectional views.INVENTED OUTLINES · NO ANATOMY, MILLIMETRES OR ACCEPTANCE THRESHOLD
Original registration concept: local correspondence does not establish agreement throughout the datasets. The visible differences are illustrative and have no numerical clinical meaning.

For discussion, inspect distributed reference regions and relevant sectional views. If correspondence is unclear, investigate the source data and alignment before relying on the combined scene.[7]

Study data registration & verification

05 / The intended restoration

Add the teeth you are planning to provide.

A useful planning discussion connects the proposed teeth, available anatomy and clinical constraints. The focused restorative-planning chapter develops these relationships through the existing bridge-planning film.[2]

Existing coDiagnostiX planning-film still for two separate upper-jaw implant bridges supported by three and two implants.

Continue with the existing film

Two bridges. Three implants + two implants.

The upper-jaw example contains two separate implant-supported bridges. It is a partial-arch restoration, not a complete-arch bridge. The implant number and distribution belong to this case.

Continue to restorative planning

06 / A quality checkpoint

Make the unresolved questions visible.

Use this discussion checklist before moving into virtual planning. It is an educational synthesis, not a validated pass/fail instrument.

  1. 01

    Record identity and timing

    Do the files belong to the intended case, and when were they acquired? Has relevant anatomy, a restoration or the treatment objective changed since acquisition?

  2. 02

    Diagnostic usefulness

    Are the required regions represented, and are artefacts or incomplete surfaces hiding important information? What remains uncertain after the clinical and imaging review?

  3. 03

    Alignment review

    Which common structures support the match? Have different regions and appropriate sectional views been checked, rather than relying on one favourable view?

  4. 04

    Planning handover

    Is the proposed restoration identified? Are the unresolved questions, reviewed datasets, reviewer and agreed next step recorded for the team?

07 / Discussion & evidence

A convincing display is the start of a conversation.

Invented teaching scenario / No patient data

The anterior overlay looks convincing.

An anterior region looks closely aligned. Posterior restorations create artefacts, and the records were acquired at different visits. A restorative proposal is present, but some of its assumptions remain unconfirmed.

  1. Which parts of the clinical and record history would you clarify?
  2. Where else would you inspect the registration?
  3. What uncertainty would you record for the planning team?
  4. What would need resolving before the next planning step?
Does a successful automatic match mean the datasets are ready?

It means the software has produced a registration. Its correspondence with the source data and intended use still needs review. The cited study evaluates registration influences; it does not validate an automatic acceptance decision.[7]

Can a surface scan replace the clinical examination or radiographic information?

An optical scan captures surfaces. It does not provide the same information as an examination or a radiographic volume. Choose and interpret each record for its particular purpose.[1][3]

Does better digital accuracy prove better long-term treatment outcomes?

Registration agreement, impression accuracy, implant-placement deviation and long-term clinical outcomes are different endpoints. Identify which one a study actually measured before extending its conclusion.[5][6]

Optical acquisition

Mangano’s review explains optical impressions, clinical uses and acquisition limitations. Its 2017 technology context should not be mistaken for a comparison of current devices.[3]

Registration

Flügge examined 36 patient datasets for registration influences. Han’s study followed a workflow involving 30 patients and 56 implants, comparing surface and fiducial registration. Their acquisition methods and study questions differ.[4][7]

Impression accuracy

Flügge’s review includes predominantly experimental evidence, with heterogeneous methods. Read the setting and the measured endpoint before applying a finding clinically.[5]

Clinical transfer

Tahmaseb’s review reports differences between planned and placed implants across clinical studies. A virtual position is not a promise of exact transfer.[6]

08 / Scientific reading

Know what each source actually supports.

The chapter combines professional recommendations, a digital consensus report and studies with different endpoints. The original concept maps and discussion exercise are OsteoPerio teaching material; they are not figures reproduced from these papers.

  1. [1] Consensus clinical recommendations / 2026

    ADA/AAOMR: patient selection for dental imaging

    Benavides E, Krecioch JR, Allareddy T, et al. Journal of the American Dental Association. 157(1):20–35.e5. doi:10.1016/j.adaj.2025.10.013.

    Clinical findings and previous images inform selection. These US recommendations are scientific reading, not a statement of Spanish regulatory requirements.

  2. [2] Consensus report / 2018

    ITI consensus: digital technologies in implant dentistry

    Wismeijer D, Joda T, Flügge T, et al. Clinical Oral Implants Research. 29(Suppl 16):436–442. doi:10.1111/clr.13309.

    Connects digital diagnosis, planning and clinical transfer; digital tools remain adjuncts to comprehensive assessment.

  3. [3] Literature review / 2017

    Intraoral scanners: principles and clinical applications

    Mangano F, Gandolfi A, Luongo G, Logozzo S. BMC Oral Health. 17:149. doi:10.1186/s12903-017-0442-x.

    Explains optical surface acquisition and its limitations. This foundational review does not rank current scanner models.

  4. [4] Clinical accuracy study / 2021

    Dental surface versus fiducial registration in guided implant surgery

    Han YT, Lin WC, Fan FY, et al. Journal of Clinical Medicine. 10(18):4183. doi:10.3390/jcm10184183.

    Thirty patients and 56 implants; workflow-specific findings. The optically scanned casts were produced with a desktop scanner, not an intraoral scanner.

  5. [5] Systematic review and meta-analysis / 2018

    Accuracy of digital and conventional implant impressions

    Flügge T, van der Meer WJ, Gimenez Gonzalez B, et al. Clinical Oral Implants Research. 29(Suppl 16):374–392. doi:10.1111/clr.13273.

    Evidence was predominantly experimental and heterogeneous. Laboratory accuracy cannot be assumed to establish clinical performance for every indication.

  6. [6] Systematic review and meta-analysis / 2018

    Accuracy of static computer-aided implant surgery

    Tahmaseb A, Wu V, Wismeijer D, Coucke W, Evans C. Clinical Oral Implants Research. 29(Suppl 16):416–435. doi:10.1111/clr.13346.

    Clinical studies report deviations between planned and placed implants. Mean values do not define a guaranteed result or a universal case-specific clearance.

  7. [7] Registration accuracy study / 2017

    Registration of CBCT data and intraoral surface scans

    Flügge T, Derksen W, Te Poel J, et al. Clinical Oral Implants Research. 28(9):1113–1118. doi:10.1111/clr.12925.

    Thirty-six patient datasets; examines reconstruction, operator and restoration-related influences. These system-specific findings do not certify every planning workflow.