Skip to content
Digital planning learning map

OsteoPerio Academy / Digital planning / Chapter 04

Surgical guides.
From the first record to clinical verification.

Learn how the whole workflow connects. Or work with OsteoPerio on guide planning, design, STL files, printing and delivery.

For qualified dental professionals. English teaching draft · Clinical review pending. Training and production requests are scoped individually before arrangements are confirmed.

From the clinical question to a reviewed guide workflowAn original eight-stage learning map. Records, registration, clinical plan and guide design form the first row. Production, verification, clinical use and review form the second. Numbered stages connect decisions with review checkpoints; this is not a validated clinical release protocol.A guide is one part of a connected workflow.Read each stage. Explain what must be reviewed before the next.1RecordsClinical question2RegistrationCheck correspondence3Clinical planReview the objective4Guide designDefine the transfer5ProductionFollow the workflow6VerificationInspect fit & system7Clinical useVerify in context8ReviewDocument & learnClinical judgement connects every stage.ORIGINAL LEARNING MAP · NO NUMERICAL ACCURACY OR TREATMENT PRESCRIPTION
The learning sequence follows the complete handover. A well-designed guide still depends on the records, production process and clinical checks around it.
Open the full chapter directory

01 / Start with the task

What is this guide meant to do?

A guide transfers a defined part of a reviewed plan. Begin by naming that task, the structures supporting the guide and the elements still controlled by the clinician. These are different questions.[14]

Purpose

An implant guide, a sinus-window template and a corticotomy marking guide transfer different information. Describe the intended job before discussing the design.

Support

Identify where the guide rests. Tooth, mucosal, bone, implant or combined support must be considered in the context of the procedure.

Extent of guidance

For implant treatment, distinguish pilot guidance, preparation guidance and guidance that also includes implant insertion. Use the terminology of the actual system.

02 / Before CAD

Begin with an agreed clinical brief.

Record selection, interpretation and registration come before guide design. The treating clinician’s assessment and the restorative objective provide the context; a matched dataset does not establish a diagnosis.[2][7]

The clinical question
Intended treatment, site, restorative objective, relevant findings and the precise function requested from the guide.
The records
Appropriate imaging and surface records, acquisition dates, clinical photographs and restorative or occlusal information needed for the task.
The system and setting
Proposed components, actual guided kit if applicable, access constraints and the team undertaking clinical treatment.
The review boundary
What is approved, what remains uncertain and which changes require another clinical/design review.

03 / Support & stability

Know where the guide rests.

Support type, distribution and fixation are relevant to accuracy. The systematic review includes both laboratory and clinical evidence; its comparisons do not make one support design appropriate for every case.[13]

Guide support: identify the actual contact surfaceThree abstract support-contact diagrams, not anatomical sections or guide CAD designs. Green guide bars touch respectively white tooth-support symbols, a pink soft-tissue band and a beige exposed-bone band. Gold dots mark conceptual contact. Fixation is a separate design decision; hybrid support is also possible.What actually supports the guide?The contact surface and the fixation strategy are separate questions.Tooth supportContact with teethCONTACT CONCEPT / NOT ANATOMYMucosal supportContact with soft tissueCONTACT CONCEPT / NOT ANATOMYBone supportContact with exposed boneCONTACT CONCEPT / NOT ANATOMYHybrid support and additional fixation may be considered.Selection depends on the site, intended task and agreed clinical workflow.SCHEMATIC CONTACTS ONLY · NO IMPLANT POSITIONS, TISSUE THICKNESS OR FIXATION RECIPE
These support-contact concepts explain where the guide rests. They do not prescribe a design, rank the options or show how many fixation points a case needs.

Tooth-supported discussion

Which teeth are used, what is their current condition, and how does the design behave beside a bounded space or a distal extension?

Mucosal or bone-supported discussion

What tissues are represented by the records, what clinical access is intended and how will seating and stability be assessed?

Retention and fixation discussion

Does the plan need additional stabilisation? Where and how can it be assessed within the actual anatomy and selected system?

04 / Guide + instruments + access

A digital hole is not a complete guided system.

The guide, guidance interface and instrument must work togetherAn original exploded system diagram. A grey instrument is aligned above a gold guidance interface, a green guide body and an abstract support surface. Dotted lines indicate a conceptual common axis. The parts are deliberately separated for explanation: the figure does not define a real kit, sleeve seating position, drilling depth, dimensions or clinical clearance.Design the guide around the intended system.Exploded relationship diagram / not an assembly or drilling instructionInstrumentConfirmed guided kit and accessGuidance interfaceSleeved or other system designGuide bodyCoverage, support and inspectionSupport surfaceVerified against the clinical planEXPLODED CONCEPT · SYSTEM-DEPENDENT GEOMETRY · NO DEPTH, OFFSET OR DRILLING SEQUENCE
The separated parts make their relationship visible. Actual interfaces, component positions and use are governed by the selected system and its instructions.

Review the complete combination.

The guidance interface, instruments and clinical access belong in the same discussion as the guide body. The selected components and intended extent of guidance must agree.[14][18]

  • Which kit and components are actually available to the treating team?
  • What is guided during this procedure, and what remains under direct control?
  • Can the planned combination be introduced and used at the site?
  • Which current instructions govern the software, components and use?

The figure deliberately separates the parts for explanation. It gives no drilling sequence, sleeve offset, preparation depth or interchangeable-system claim.

05 / The design review

Make each design decision explainable.

Our teaching uses a design conversation: state the choice, explain its reason, show how it is reviewed and document what needs approval. Use current instructions for the installed software version and the selected system.[15]

Task & extent of guidance

Is this a pilot guide, a guide for a defined preparation sequence, implant placement guidance, an access-window template or a marking guide?[14]

Document: State exactly what is guided and what is not.

Support & stability

Which surfaces support the guide? How does the plan address loss of support, tissue movement, a free end or the need for fixation?[13]

Document: Identify the support and the seating-verification strategy.

Components & clinical access

Do the selected guide interfaces and actual instruments belong to the intended workflow? Can the assembly be used at the planned site?[14][18]

Document: Confirm the system, kit, components and access review.

Coverage, insertion & inspection

Can the planned guide be inserted and its seating assessed? How does its coverage relate to the clinical approach and the structures being used for support?[14]

Document: Review the design in context, not only as an isolated mesh.

A guided CAD review / Our teaching framework

Work through the design in six passes.

  1. 01

    Define the object to transfer

    Identify the reviewed restoration, implant plan or surgical marking. Make clear which objects are reference data and which belong to the proposed guide.

  2. 02

    Review the guide footprint

    Discuss the covered surfaces, support distribution, path of insertion and the clinical approach. Explain how the design can be inspected for seating.

  3. 03

    Relate the interfaces to the kit

    Review the selected component information with the actual instruments and intended task. Resolve any uncertainty about the combination before approval.

  4. 04

    Inspect the design from different views

    Explain how the guide relates to its support and planned task. A pleasing exterior view should not be the only view used in the discussion.

  5. 05

    Review the export and its identity

    Identify the approved revision and the agreed file, units/scale and companion information. Keep a review copy distinct from a version released for production.

  6. 06

    Close the review loop

    Record the remaining questions, who reviews them and what can proceed. If the plan or relevant records change, identify which approval must be revisited.

The result is a reviewed design version with a defined task. A late change to the plan, support, components or clinical records calls for review of the affected design and handover—not an unnoticed change to the exported file.

06 / OsteoPerio design & fabrication

The print is part of the process.

OsteoPerio handles surgical-guide design and fabrication. We discuss the intended use and the complete production route with the requesting clinician, whether the agreed output is a digital design or a printed guide.

Manufacturer workflows connect scanning and design with printing, washing, post-curing, finishing, assembly and preparation for use. These steps are specific to the selected material and equipment; a generic resin setting or cycle is not a substitute for their instructions.[16]

  1. 01

    Approve the design version

    Identify the plan, intended use and final design. Resolve outstanding clinical or technical questions before an export is treated as approved.

  2. 02

    Define the production route

    Confirm the responsible producer, compatible equipment, intended material and applicable instructions. Agree who supplies and assembles any components.

  3. 03

    Produce and process

    Follow the selected manufacturing workflow, including the required finishing and post-processing. These steps depend on the actual material and equipment.

  4. 04

    Inspect and document

    Check the produced guide and relevant components, record the released version and resolve discrepancies. A manufacturing check does not replace clinical seating verification.

  5. 05

    Prepare the handover

    Confirm identification, instructions, processing state, storage/transport conditions and the receiving clinician’s next checks before dispatch or file delivery.

07 / Different checks / Different questions

Verify the guide in its clinical context.

Errors can arise at different stages and combine. Review at each handover is therefore part of the workflow, rather than a single final inspection.[18]

A model check

Does the guide correspond to the intended model and design? What can be inspected here, and what still depends on the patient and the procedure?

A clinical seating check

Can the treating team verify the intended seating, support and stability in the actual clinical situation?

An instrument and access check

Does the planned guide work with the confirmed components and available clinical access? Is the intended preparation understood?

A discrepancy decision

If seating, components, integrity or the current anatomy do not agree with the plan, pause the guided workflow for clinical and technical reassessment. Do not assume pressure or unreviewed alteration will resolve the cause.

Published planned-to-placed deviations describe an accuracy endpoint. They do not guarantee an individual guide’s performance or define a universal case-specific clearance. A clinical team still needs a plan for uncertainty and for an unsuitable guide.[6]

08 / Digital or physical delivery

Choose the output. Agree the whole handover.

An STL design and a printed guide are different deliverables. Before work starts, agree what OsteoPerio will provide, what the receiving team will do and who approves the clinical plan.

Compare STL design delivery with a printed guide and delivery request
Agree in advanceDesign + STLDesign + printed guide
Main outputReviewed design export and the agreed plan/component information.The fabricated guide and the agreed components and documentation.
ProductionYour agreed producer uses the approved export in its manufacturing workflow.OsteoPerio fabricates the guide under the agreed production arrangement.
ProcessingReceiving producer/team confirms its required processing and preparation steps.Supply state and any further preparation are explicitly agreed; shipping does not imply sterility.
Before clinical useTreating team verifies the produced guide, current clinical fit and system compatibility.Treating team verifies the received guide, current clinical fit and system compatibility.
Costs and timingConfirmed after scope, compatibility and file requirements are reviewed.Confirmed after scope, production needs, destination and logistics are reviewed.

Six things to clarify in every handover.

01Clinical scope
Intended task, treating clinician, reviewed plan and the parts of the procedure that remain outside the guide’s function.
02Version & files
Agreed design revision, labelled export, units/scale confirmation and identification of any accompanying model or review files.
03Components
Guide-system and kit information, relevant sleeves or interfaces, and what is supplied versus sourced by the receiving team.
04Production & processing
Responsible producer, material/process information, inspections and the agreed instructions for further preparation.
05Delivery & receipt
Delivery route, recipient, timing and what the team should check on receipt. Do not infer a sterile supply state.
06Clinical verification
Who verifies seating, stability, access and compatibility in the mouth, and how an unresolved discrepancy is escalated.

This is a discussion framework for agreeing a request, not a claim that every item is supplied in every package. Clinical prescription/approval, design, manufacture and final clinical verification have distinct responsibilities.

09 / Connect the concepts with existing records

Different tasks. Different guides.

Inside a planning case

1 min 24 sec · No narration

An upper-jaw planning model for two separate bridges, supported by three implants and two implants, with bone anatomy and guide components

Two upper-jaw implant bridges: three implants + two implants.

The rotating coDiagnostiX view shows the plan for two separate upper-jaw bridges: one supported by three implants and the other by two. This is a partial-arch restoration, not a full-arch bridge. Surface scans, bone anatomy and restorative and guide components help explain the planning relationships.

A digital planning demonstration. The implant number, guide design and treatment stages are specific to the individual case.

Read this example with a design question

Two upper-jaw bridges: three implants + two.

Use the existing coDiagnostiX film to identify the restorative groups, the displayed records and the guide components. This is a partial-arch planning demonstration; it does not document guide manufacture, clinical seating or the surgical outcome.

  • What is the intended function of the displayed guide?
  • Which structures appear relevant to support, and what needs clinical confirmation?
  • What additional records would you need before approving production?
Read the complete planning discussion
Existing sinus-window planning video poster with the printed guide shown below the digital model

A guide for access-window planning

Guided sinus-window example

Follow the existing digital planning film, printed guide and intraoperative sequence. The window guide’s task and implant-placement timing are separate parts of the plan.

Explore the sinus sequence

Linked sequence contains surgical photographs.

Existing printed maxillary model and separate right and left corticotomy marking guides, with one guide also shown alone

A guide for transferring markings

Guided corticotomy example

See the model and separate guides, then follow the marking-guide workflow. Surgery: Dr. Sahand Shirzadi Maryan. Guide design and printing: Dr. Behnam Taghavi.

Explore the documented case

The existing case retains its clinical sequence, credits and early-follow-up limits.

10 / How we structure the teaching

From foundations to a reasoned workflow.

Begin at your current level. We can connect theoretical preparation and article discussion with software-based planning, guide-design review and the production workflow. The modules below show how a complete learning pathway can be organised with OsteoPerio.

Each module has a practical discussion, an output to explain and a checkpoint to defend. Exercises, software access, teaching language, duration and fees are agreed individually. This is a curriculum framework, not a scheduled or accredited course.

  1. 01Build the clinical briefOpen / close

    Understand

    Define the treatment objective, proposed restoration and the precise job of the guide. Separate implant guidance, window positioning and surgical marking.[2][14]

    Work through it

    Discuss a case brief with the tutor: what will the guide control, what remains under direct clinical control, and which alternatives need consideration?

    Your learning output

    A written indication, named treating clinician and a list of unresolved questions.

    Discussion checkpoint: Can you explain why this guide is needed, rather than beginning with a software feature?

  2. 02Read and align the recordsOpen / close

    Understand

    Distinguish radiographic volume, optical surfaces, occlusion, photographs and the restorative proposal. Review their identity, timing, coverage and correspondence.[7]

    Work through it

    Inspect a teaching dataset in different views. Explain where the registration is convincing and where you need further information.

    Your learning output

    A record inventory and a documented registration review.

    Discussion checkpoint: A convincing rendered surface is not enough to accept the match.

  3. 03Review the restorative and surgical planOpen / close

    Understand

    Relate the intended teeth to anatomy, tissue needs, access and the proposed treatment stages before designing the transfer tool.[2]

    Work through it

    Present the plan and an alternative. Identify the assumptions requiring the treating clinician’s review.

    Your learning output

    A reviewed plan with an explicit version and scope of guidance.

    Discussion checkpoint: Guide design follows clinical planning; it does not resolve an uncertain diagnosis.

  4. 04Choose support and guidanceOpen / close

    Understand

    Compare the support surface, retention or fixation strategy, and the extent of instrument guidance. These are separate design decisions.[13][14]

    Work through it

    Compare a bounded space, a free-end situation and an edentulous teaching example. Describe what keeps each proposed guide seated.

    Your learning output

    A reasoned support concept and system-compatibility list.

    Discussion checkpoint: The same total number of implants does not imply the same guide design.

  5. 05Design and review the CAD modelOpen / close

    Understand

    Connect guide coverage, insertion path, inspection access and component placement with the intended clinical task. Use the current software and kit instructions.[15][18]

    Work through it

    Walk through a design review with the tutor. Explain how access, support, component interfaces and any proposed changes are checked.

    Your learning output

    A design-review record and the version submitted for clinical approval.

    Discussion checkpoint: Do not substitute a generic thickness, sleeve offset or drilling diagram for the selected system’s instructions.

  6. 06Follow fabrication and post-processingOpen / close

    Understand

    Trace the approved export through the selected material and production workflow, finishing, component assembly and inspection.[16]

    Work through it

    Discuss a production record and the relevant manufacturer instructions. Identify which steps belong to the specific equipment/material combination.

    Your learning output

    A production and inspection checklist for the agreed workflow.

    Discussion checkpoint: A good-looking print does not demonstrate a complete or suitable processing cycle.

  7. 07Verify and hand overOpen / close

    Understand

    Separate model checks, clinical seating, stability, component compatibility and readiness for the intended procedure.[6][18]

    Work through it

    Use a teaching guide/model to discuss fit and access. Work through a handover with the design version, component list and remaining clinical checks.

    Your learning output

    A traceable handover and a plan for resolving any discrepancy.

    Discussion checkpoint: Model fit and clinical fit answer different questions.

  8. 08Apply, review and developOpen / close

    Understand

    Connect the guide with clinical judgement, documentation and follow-up. Compare what the plan intended with what was actually observed.[6][14]

    Work through it

    Discuss an implant, sinus-window or marking-guide example. Identify what was transferred, what was verified and what the records cannot establish.

    Your learning output

    A case reflection, an evidence question and a next learning objective.

    Discussion checkpoint: Placement accuracy, clinical outcomes and the learner’s competence are different endpoints.

Prepare

Read the agreed sources and formulate your questions before the session.

Explain

Present your reasoning and review a teaching plan or design with the clinical team.

Connect

Relate the design to production and, where individually arranged, relevant clinical observation.

For qualified dentists and postgraduate clinicians. Observation does not include operating on patients. The supervised clinical programme remains in preparation and is not available to book. The downloadable brief is an educational discussion aid, not a clinical release form.

11 / Professional guide support / OsteoPerio

Tell us what you need to transfer.

You can ask OsteoPerio to plan and design a guide, send an agreed STL design, or fabricate and deliver the printed guide. Start with the task and your clinical setup. We review the request and clarify the appropriate scope before a proposal or production arrangement is confirmed.

Digital delivery

Planning & design / STL delivery

Discuss a guide design for production through your own agreed manufacturing workflow.

Define the output
Agree the reviewed design version, export files, plan summary and component information needed by your team.
Clarify before work starts
Your production setup, intended material/process, guide system, file requirements and who will manufacture and release the guide.
Email a request: STL design

Opens a draft in your email app. Review it before sending.

Physical delivery

Design, print & send the guide

Discuss guide design and fabrication by OsteoPerio, followed by delivery to the agreed destination.

Define the output
Agree the guide, relevant components, supporting documents and the condition in which it will be supplied.
Clarify before work starts
Clinical approval, kit compatibility, destination, processing responsibilities, fees, production timing and transport arrangements.
Email a request: printed guide

Opens a draft in your email app. Review it before sending.

Professional review

Discuss a plan or existing design

Start with a focused conversation about your proposed workflow, existing plan or production requirements.

Define the output
Define the review question and whether design, production support or education is the appropriate next step.
Clarify before work starts
What has already been planned, who is treating the case and which part of the workflow needs support.
Email a request: plan review

Opens a draft in your email app. Review it before sending.

12 / Questions & critical reading

Know what each part of the workflow establishes.

Can I learn this from the beginning?

Yes. We can structure individually arranged teaching from record interpretation and planning foundations through guide design and production review. The starting level, software needs, teaching language, exercises and format are agreed with you. Practical work and observation depend on the arrangement; reading the chapter does not qualify someone to perform surgery.

Can OsteoPerio design the guide and send only the STL?

Yes, you can enquire about planning, guide design and digital delivery for production through your own agreed workflow. We first clarify the clinical task, compatible system, required records, approval and manufacturing responsibilities. The STL is one deliverable; the agreed plan, design version and relevant component information also matter.

Can you print the guide and send it to my practice?

OsteoPerio handles guide design and fabrication. Tell us your intended use and delivery country so we can discuss compatibility, scope, documentation, processing responsibilities, costs and logistics. The initial enquiry is a request for review and a proposal, not an accepted production order or guaranteed delivery date.

Can you print an STL I already have?

Ask us to review the proposed file and intended workflow first. A surface file alone does not establish that the clinical plan, design, material/process and components are appropriate. Whether an externally prepared design can be accepted is agreed after review.

Are all guides, resins and guided kits interchangeable?

No. Software, guide design, materials, components, processing and instruments need to be considered as a connected workflow. Use the instructions applicable to the actual combination rather than transferring numerical settings from an unrelated example.[15][16]

Does a printed model prove the guide will fit in the mouth?

No. It offers a production/design check in a model context. The treating clinician still needs to verify the current clinical situation, seating, stability and access. An unresolved discrepancy requires reassessment before proceeding with that guide.[18]

Does a guide guarantee flapless surgery or immediate loading?

No. Guide support, surgical access, implant-placement timing and loading are separate decisions. They depend on the clinical plan and the conditions encountered; the existence of a digital guide does not settle them.[2][14]

What should I send in my first message?

Start with your professional role, country, the general guide task, the support you need, the system/kit if known and preferred timing. Do not include patient-identifying details or attach clinical files to the initial enquiry. We will clarify the appropriate records-transfer arrangements after discussing the request.

Accuracy evidence

Clinical planned-to-placed deviations and laboratory design comparisons answer different questions. Neither certifies an individual guide or proves long-term benefit.[6][13]

Workflow reasoning

A narrative review and a risk review help organise the system and its possible failure points. They do not validate this chapter as an operative protocol.[14][18]

Manufacturing instructions

A manufacturer’s application guide belongs to its own equipment/material context. Regulatory guidance also requires the actual device and production arrangement to be identified.[16][17]

13 / Scientific & technical reading

Read the evidence and the applicable instructions.

Scientific sources inform the concepts; manufacturer documents govern their specific systems. The figures, learning exercises and handover framework are original OsteoPerio teaching material. Sources do not certify or endorse OsteoPerio’s production process.

  1. [2] Consensus report / 2018

    ITI consensus: digital technologies in implant dentistry

    Wismeijer D, Joda T, Flügge T, et al. Clinical Oral Implants Research. 29(Suppl 16):436–442. doi:10.1111/clr.13309.

    Connects digital diagnosis, planning and clinical transfer; digital tools remain adjuncts to comprehensive assessment.

  2. [6] Systematic review and meta-analysis / 2018

    Accuracy of static computer-aided implant surgery

    Tahmaseb A, Wu V, Wismeijer D, Coucke W, Evans C. Clinical Oral Implants Research. 29(Suppl 16):416–435. doi:10.1111/clr.13346.

    Clinical studies report deviations between planned and placed implants. Mean values do not define a guaranteed result or a universal case-specific clearance.

  3. [7] Registration accuracy study / 2017

    Registration of CBCT data and intraoral surface scans

    Flügge T, Derksen W, Te Poel J, et al. Clinical Oral Implants Research. 28(9):1113–1118. doi:10.1111/clr.12925.

    Thirty-six patient datasets; examines reconstruction, operator and restoration-related influences. These system-specific findings do not certify every planning workflow.

  4. [13] Systematic review / 2023

    Accuracy of digital surgical guides: support, design and manufacture

    Shi Y, Wang J, Ma C, Shen J, Dong X, Lin D. International Journal of Implant Dentistry. 9:38. doi:10.1186/s40729-023-00507-w.

    Includes laboratory and clinical studies. Design comparisons and manufacturing findings need to be read within those different settings.

  5. [14] Narrative review / 2025

    Static computer-assisted implant surgery: terminology, systems and limitations

    Yeo XH, Fan S, Chantler JGM, Chow J, Pimkhaokham A, Mattheos N. Australian Dental Journal. 70(Suppl 1):S129–S145. doi:10.1111/adj.70007.

    Explains guide and instrument-system concepts. An overview is not a validated recipe for every design or clinical indication.

  6. [15] Manufacturer instructions portal / 2026

    coDiagnostiX: current instructions for use

    Dental Wings. Official electronic instructions portal. Accessed 30 October 2026; select the applicable version and language.

    Use the instructions relevant to the installed software. Listing this resource does not establish the software version used for a particular case.

  7. [16] System-specific technical guidance / 2026

    A manufacturer example: scan-to-production surgical-guide workflow

    Formlabs Dental. Application Guide: 3D Printing Surgical Guides. Official resource, accessed 30 October 2026.

    An example of connected manufacturing steps. Its settings are not universal or a statement of OsteoPerio’s equipment, material or processing protocol.

  8. [17] Regulatory guidance / 2021

    Custom-made, adaptable and patient-matched devices: MDCG 2021-3

    Medical Device Coordination Group. Questions and Answers on Custom-Made Devices. March 2021. Non-binding regulatory guidance.

    Distinguishes device categories and responsibilities. A patient-specific design is not automatically a custom-made device or proof of compliance.

  9. [18] Clinical risk review / 2019

    Guided implant surgery risks and their prevention

    Tatakis DN, Chien HH, Parashis AO. Periodontology 2000. 81(1):194–208. doi:10.1111/prd.12292.

    Discusses errors across the workflow, the need for verification and the importance of system knowledge and surgical experience.