Window planning
Transfer the selected access outline in relation to the planned anatomy.
OsteoPerio Academy / Sinus augmentation / Chapter 04
Connect three-dimensional sinus assessment to a printed access guide, then follow the existing clinical planning and surgical sequence.
Explore the clinical sequenceQualified dentists and postgraduate clinicians · English chapter · Clinical review pending.

01 / Begin with the intended transfer
Transfer the selected access outline in relation to the planned anatomy.
Assess lining integrity, release and the intended graft compartment during the operation.
Decide separately whether implantation is guided, simultaneous or staged.
The documented guide is for the sinus access window. A guide designed to transfer a contour is not, by that description alone, a depth-control device or an implant-placement guide.[1][2]
02 / Build the plan from the records
01
Relate the intended reconstruction to the residual ridge, sinus floor, septa and vascular anatomy. Imaging should answer the clinical question, with an appropriate field of view.[3]
02
When surface records and CBCT are combined, inspect correspondence across views and identifiable structures. An attractive rendered model is not proof that the records are aligned correctly.[3][5]
03
Relate the proposed window to the floor, relevant structures and the area that must be reached. Preserve visibility and working access for the subsequent operation.[4][6]
04
Define the contour or other intended guidance, its support and the planned instrument relationship. Record which parts of the operation remain outside the guide’s task.[1][2]
03 / Connect the stages
Use the existing guide-workflow map to locate the sinus-window task. Planning, manufacture and clinical use depend on the records and checks around them.[1][5]
Once the window is prepared, membrane assessment and elevation remain anatomical and clinical tasks. The access guide does not demonstrate tissue integrity or decide how a complication should be managed.[4]
Study guide design, production and verificationA real planning and surgical sequence
See the guide being designed digitally, the printed guide and its use during a lateral-window procedure. This example shows one possible approach; your own technique and treatment stages depend on your assessment.
The guide shown here is designed for the sinus access window. The decision about when to place implants is a separate part of the treatment plan.
01–02 · Planning video
Play the 40-second video · no sound
Upper view: digital planning. The software view rotates around the three-dimensional anatomy and shows the guide design.
Lower view: the printed guide. The physical guide is shown beneath the digital planning sequence.
Open the planning video03 · During surgery
Clinical photographs · contains surgical views

Upper photograph: guide in position. The printed guide is placed at the planned surgical site.
Lower photograph: after window osteotomy. The opening made in the side of the bone is visible after preparation of the lateral window.
View the surgical photographs at full sizeThese records show planning and intraoperative stages, not a healed result. They do not establish whether you need a guide, a sinus lift or implants at the same operation.
Compare the planning record with two intraoperative photographs. For each view, decide what you can confirm and what needs a separate clinical check.

It documents the planned lateral access and the guide’s intended shape. Review the source sections to judge the access relative to the sinus floor, any septa and nearby structures. The printed guide is also visible in the full film.
Confirm the registered records and the intended task of the guide before relying on the design.
Scientific reference 1The trial compared guided and freehand surgery in 40 patients, 20 per group. The guided group averaged 11.4 minutes for the window osteotomy versus 18.6 minutes for freehand, and patients reported more swelling on day two. With this sample, the effect on complication rates remains uncertain. Narongchai et al., 2025
04 / Design intent must survive clinical use
The support illustration is an abstract learning tool. Identify the actual contact surfaces and fixation strategy in the individual guide; do not assume that a rendered or printed model proves clinical seating.[5]
Confirm the site, current records, registration and approved access plan before production.
Does the guide correspond to the plan that will actually be used?
Use the validated process for the selected material and intended use. Inspection, post-processing and disinfection or sterilisation follow the applicable instructions.
Is the production and processing record available?
Inspect the support contacts and stability in the intended clinical conditions. Check visibility, irrigation and instrument access.
Can the guide seat reproducibly without being forced?
Reassess fit and the clinical field before use. If seating, visibility or access is inadequate, revisit the plan and the appropriate alternative.
What finding would make you stop using this guide?
Original review prompts, connected to references 1, 5 and 6 and the shared guide-production chapter. Material processing is governed by its applicable instructions, not a universal website recipe.
The window-guide review included a small, mostly descriptive evidence base. A 2025 randomized study of 14 patients did not find a significant difference in complication outcomes. It also guided implant placement, so it does not isolate the effect of a window-only template.[1][2]
05 / Test the reasoning
Discussion 01
A surface model looks aligned, but a second sectional view disagrees. Can the guide be released for production?
Discussion 02
Would holding it firmly against the teeth establish reliable transfer?
Discussion 03
Does a window contour establish cutting depth, lining integrity or simultaneous implant suitability?
Invented professional teaching prompts, not findings reported for the documented patient.
Continue with complication prevention and management06 / Scientific reading
The clinical sequence, abstract study figures and written framework are teaching materials. Window-guide studies, implant-guidance accuracy reviews and anatomical reviews address different questions. Their findings do not certify this guide, its fit or a patient-specific safety distance.
[1] Systematic review of window-guide reports / 2025 print / 2024 online
The Use of CAD/CAM Templates in a Lateral Sinus Floor Augmentation Procedure: A Systematic ReviewPeña-Cardelles JF, Núñez Díaz F, Kotina E, Pedrinaci I, Lanis A, Gallucci GO. International Journal of Periodontics & Restorative Dentistry. 45(2):253–261. doi:10.11607/prd.6919.
Thirteen studies included 94 lateral procedures, mostly from case reports or series. The small comparative evidence base does not establish complication-free guided surgery.
[2] Small randomized clinical study / 2025
Assessment of guided lateral maxillary sinus lift procedure with simultaneous implant placement using stereolithographic surgical guide: a randomized controlled clinical studyHussein W, Younis A, Elrawdy A, ElSholkamy M. Oral and Maxillofacial Surgery. 29:102. doi:10.1007/s10006-025-01399-3.
Fourteen patients received 30 implants. The protocol guided both window preparation and implant placement; it is not the same task as a window-only guide. Complication outcomes did not differ significantly between groups.
[3] Imaging narrative review / 2023
CBCT for Diagnostics, Treatment Planning and Monitoring of Sinus Floor Elevation ProceduresMorgan N, Meeus J, Shujaat S, Cortellini S, Bornstein MM, Jacobs R. Diagnostics. 13(10):1684. doi:10.3390/diagnostics13101684.
Explains sectional evaluation and the role and limits of three-dimensional imaging. Not a reason to repeat CBCT routinely.
[4] Clinical narrative review / 2025 issue / 2024 online
Prevention and management of intra-operative complications in maxillary sinus augmentation: A reviewValentini P, Stacchi C. Clinical Implant Dentistry and Related Research. 27(1):e13397. doi:10.1111/cid.13397.
Explains operative risk, repair options and limitations of containment. Technique proposals are not one universally validated rescue protocol.
[5] Implant-guidance accuracy review / 2018
The accuracy of static computer-aided implant surgery: A systematic review and meta-analysisTahmaseb A, Wu V, Wismeijer D, Coucke W, Evans C. Clinical Oral Implants Research. 29(Suppl 16):416–435. doi:10.1111/clr.13346.
Supports attention to the complete transfer workflow. Implant-position deviations are not validated accuracy or safety margins for a sinus-window guide; no numerical values are transferred here.
[6] Systematic review with an older search window / 2024
Effect of a CAD-CAM sinus surgical template on the outcome of sinus augmentation. A systematic reviewMazaheri Nazarifar A, Mohamad Sharifi H, Habib Khodaei M, Davoudi A. Stomatologija. 26(1):18–23.
Five studies were included; the search ended in November 2019. Discusses possible benefits and access limitations, but does not describe the current evidence base or certify a specific guide.