Skip to content
OsteoPerio
Implant surgery learning map

Can a short implant support a single posterior crown?

Read 4, 6 and 10 mm implant lengths against site anatomy, the proposed restoration, device indications and clinical follow-up.

Professional education · Clinical review pending

Compare the implant body lengths

The 4, 6 and 10 mm bodies are drawn in proportion to one another. The crown and shoulder stay at the same height. The 4 mm drawing represents length in a generic section. The named Standard Plus example below has its own tissue-level collar and restorative indication.

4 mm endosseous lengthThe planned crown and crestal reference match the other panels. The dimension line spans the threaded implant body.4 mm
4 mm implant body
6 mm endosseous lengthThe planned crown and crestal reference match the other panels. The dimension line spans the threaded implant body.6 mm
6 mm implant body
10 mm endosseous lengthThe planned crown and crestal reference match the other panels. The dimension line spans the threaded implant body.10 mm
10 mm implant body

What would change your plan?

Anatomy at the intended implant position

Review height and width in the planned trajectory, proximity to the sinus or mandibular canal, and whether primary stability is achievable. Document any need for augmentation or a different restoration.

The exact implant and restoration

Record the manufacturer and reference, endosseous length, diameter and collar. Check the current instructions for use for the intended restoration. Distinguish a single crown, splinted adjacent crowns, a pontic and a cantilever.

Loading and maintenance

Review crown height, occlusal contacts, opposing dentition and parafunction. Compare prosthetic and surgical complications as well as implant survival. Plan hygiene access and follow-up before committing to the restoration.

Work through the cases

Choose a response to see the reasoning. Try another answer to compare.

Two 4 mm fixtures in a distal-extension mandible

A colleague proposes two individual crowns in a severely resorbed posterior mandible. The proposed implants are 4 mm long and the product reference is missing.

What do you need before deciding whether to assess a splinted or unsplinted restoration?

One upper molar with limited height under the sinus

A patient needs one posterior maxillary crown. The planned crown is available and native bone height may accommodate a 6 mm implant. Ridge width at the planned position and sinus assessment still need review.

How would you use the ten-year data in the discussion?

What the 4 and 6 mm evidence covers

Read the device indication, the 4 mm splinted series, the 4 mm single-crown pilot and the 6 mm trials separately. Each addresses a specific device, jaw or restoration. The numbers below describe the study groups.

  1. 6th ITI Consensus Conference · Posterior sites

    Short implants at posterior sites

    The consensus defined short as 6 mm or less. It recommends splinting restorations on adjacent short implants and urges caution with an isolated missing molar or parafunction. Use the device indication separately.

    Read the source
  2. Straumann España · Technical manual 702084 and product labelling

    The specific 4 mm Standard Plus example

    The Spanish table describes the 4 mm Roxolid Standard Plus with a 4.1 mm body and regular neck in severely resorbed distal-extension mandibular sites, with splinted units and one implant per unit. The corresponding product reference is 033.043S. Retrieve the current instructions for use for that reference and country before applying this indication.

    Read the sourceManufacturer’s instructions portal
  3. Slotte et al. · Prospective multicentre study · 2015

    Splinted 4 mm implants in the posterior mandible

    Twenty-eight patients and 86 implants supported splinted three- or four-unit restorations, with one implant per unit and without pontics or cantilevers. Five-year outcomes describe that configuration.

    Read the source
  4. Leighton et al. · Prospective pilot study · 2022

    Single 4 mm implants in mandibular first-molar sites

    All 18 implants survived three years and one prosthetic screw loosened. The uncontrolled pilot provides preliminary evidence for the studied site and restoration. Use the current instructions for use to check whether the selected device permits the proposed restoration.

    Read the source
  5. Sahrmann et al. · Randomised trial · 2023

    Single posterior crowns on 6 and 10 mm implants at ten years

    Of 94 randomised patients, 70 attended the ten-year reassessment. Reported survival was 85.7% for 6 mm and 97.1% for 10 mm (p = 0.072). The estimate leaves uncertainty about equivalence. The study used screw-retained crowns and regular professional maintenance.

    Read the source
  6. Guljé et al. · Randomised trial · 2024

    Posterior maxillary single crowns with or without sinus augmentation

    This small study reported ten-year survival of 89.5% for 6 mm implants alone and 90.9% for 11 mm implants with sinus augmentation. Use it when discussing alternatives in a similar posterior maxillary case, alongside surgical burden, anatomy and follow-up.

    Read the source
Compare implant timing in the sinus chapter