Skip to content
OsteoPerio
Implant surgery learning map

OsteoPerio Academy / Implant surgery / Chapter 06

Protect the healing.
Verify the next step.

Connect biological healing, provisional design and clinical assessment to a reasoned loading and restorative plan.

Explore the healing guide

For qualified dentists and postgraduate clinicians · English chapter · Clinical review pending.

02 / Covered healing or a transmucosal component?Two bone-level implant examples: a cover screw beneath closed mucosa, and a smooth healing abutment passing through mucosa. Threaded bodies and shoulders remain in bone. Neither drawing includes a crown. These configurations do not, by themselves, establish the loading protocol, prove successful integration or prescribe a surgical approach. Original educational schematic, not to scale. Clinical review pending.SURGICAL HEALING CONFIGURATION · CORONAL UPSubmerged healingClosed mucosaCover screwBone-level fixture entirely within boneTransmucosal healingHealing abutmentBoneBone-level fixture entirely within boneA healing abutment is not a tooth or a loading decision.Separate examples · No crown shown · Simplified tissue relationships
Covered and transmucosal healing: neither example includes a crown. The bone-level fixture stays within bone; a smooth healing component may pass through mucosa.

01 / Biology and clinical measurements answer different questions

Healing is a process. Loading is a decision.

Initial engagement and bone response

Mechanical engagement at placement differs from the subsequent formation and remodelling of bone at the interface. The biological review describes woven-bone formation followed by maturation and continuing remodelling. These processes do not provide one integration date for every site.[1]

Measure consistently; interpret in context.

Insertion torque records rotational resistance during placement. Resonance frequency analysis reports a different stability measurement. The cited systematic review found low-certainty evidence for their relationship: do not convert torque into ISQ or assume they are interchangeable scales.[3]

For a teaching case, state what was measured, when and in which clinical context. Avoid treating a reassuring number as a direct picture of the whole interface. The first diagram intentionally omits a universal “stability dip” curve and numerical clearance threshold.

02 / Four original study plates

Separate configuration, timing and readiness.

Enlarge the diagrams to compare biology, healing components, loading terminology and the clinical handover. The anatomy uses bone-level fixtures; the protocol cards are not a proportional time axis.

01 / Mechanical engagement and biological healingInitial mechanical engagement and subsequent bone formation/remodelling are different contributors to implant stability. The arrows indicate conceptual relationships, not measured strength, separate non-overlapping phases or a universal week-by-week stability curve. Remodelling continues beyond the first restorative visit. Original educational schematic, not to scale. Clinical review pending.STABILITY HAS A MECHANICAL AND A BIOLOGICAL CONTEXTInitial mechanical engagementBiological responseEngagement with the prepared siteBone formation and remodellingClinical assessment remains essentialA calendar date or single number does not show the whole interface.Conceptual inset · Gold highlights the interface, not a measured amount of new boneNo strength scale, universal stability dip or time-to-integration is depicted.

01 / Mechanical engagement and biological healing

Initial mechanical engagement and subsequent bone formation/remodelling are different contributors to implant stability. The arrows indicate conceptual relationships, not measured strength, separate non-overlapping phases or a universal week-by-week stability curve. Remodelling continues beyond the first restorative visit.

Original educational schematic · Not to scale · No patient outcome represented.

02 / Covered healing or a transmucosal component?Two bone-level implant examples: a cover screw beneath closed mucosa, and a smooth healing abutment passing through mucosa. Threaded bodies and shoulders remain in bone. Neither drawing includes a crown. These configurations do not, by themselves, establish the loading protocol, prove successful integration or prescribe a surgical approach. Original educational schematic, not to scale. Clinical review pending.SURGICAL HEALING CONFIGURATION · CORONAL UPSubmerged healingClosed mucosaCover screwBone-level fixture entirely within boneTransmucosal healingHealing abutmentBoneBone-level fixture entirely within boneA healing abutment is not a tooth or a loading decision.Separate examples · No crown shown · Simplified tissue relationships

02 / Covered healing or a transmucosal component?

Two bone-level implant examples: a cover screw beneath closed mucosa, and a smooth healing abutment passing through mucosa. Threaded bodies and shoulders remain in bone. Neither drawing includes a crown. These configurations do not, by themselves, establish the loading protocol, prove successful integration or prescribe a surgical approach.

Original educational schematic · Not to scale · No patient outcome represented.

03 / Name the restoration and the loading intervalTerminology follows the 2018 ITI classification, measured from implant placement. Immediate restoration is held out of occlusion; immediate loading is in occlusion. The rows are equal-sized teaching cards, not a time-proportional axis. These labels neither confirm biological readiness nor state when the definitive prosthesis will be delivered. Original educational schematic, not to scale. Clinical review pending.RESTORATION / LOADING CLOCK STARTS AT IMPLANT PLACEMENT1Immediate restorationWithin 1 weekRestoration held out of occlusion with the opposing arch.2Immediate loadingWithin 1 weekProsthesis connected in occlusion with the opposing arch.3Early loadingBetween 1 week and 2 monthsTiming measured from implant placement.4Conventional loadingAfter more than 2 monthsHealing without prosthesis connection before this stage.ITI 2018 terminology · Equal-sized cards, not proportional time intervalsThe definitive prosthesis has its own readiness and verification decisions.

03 / Name the restoration and the loading interval

Terminology follows the 2018 ITI classification, measured from implant placement. Immediate restoration is held out of occlusion; immediate loading is in occlusion. The rows are equal-sized teaching cards, not a time-proportional axis. These labels neither confirm biological readiness nor state when the definitive prosthesis will be delivered.

Original educational schematic · Not to scale · No patient outcome represented.

04 / Review findings before advancing restorationA conceptual clinical handover connects healing review, support assessment, the provisional, definitive verification and continuing care. Unexpected findings lead back to assessment and an appropriate alternative. This is a discussion framework, not a complete protocol or a fixed appointment schedule. Original educational schematic, not to scale. Clinical review pending.FROM HEALING REVIEW TO A MAINTAINABLE RESTORATION01 / Review the siteTissues, healing course and unexpected findings02 / Assess the supportRecorded method, trend and clinical context03 / Review the provisionalRetention, contacts, contour and cleaning access04 / Verify definitive readinessRecords, components, fit, bite and any required try-ins05 / Record and continue careBaseline findings, patient care and individual reviewUncertain findings → reassess the plan and maintain appropriate protection

04 / Review findings before advancing restoration

A conceptual clinical handover connects healing review, support assessment, the provisional, definitive verification and continuing care. Unexpected findings lead back to assessment and an appropriate alternative. This is a discussion framework, not a complete protocol or a fixed appointment schedule.

Original educational schematic · Not to scale · No patient outcome represented.

Visible does not mean loaded.

A smooth healing abutment can traverse mucosa without a prosthetic crown. Submerged versus non-submerged healing concerns the surgical healing configuration. The comparative review specifically excluded immediate loading, illustrating that these are separate questions.[4]

A protocol label does not certify healing.

The timing card follows ITI 2018 terminology, measured from implant placement. It distinguishes immediate restoration from immediate loading by occlusal connection. A provisional’s delivery and the definitive restoration remain separate decisions.[2]

Compare the extraction and implant-placement clocks

03 / A provisional must suit the selected pathway

State how the interim teeth are supported.

Implant-retained provisional

Describe its retention and intended contacts. Review contour, surface finish, tissue relationships and access within the selected protocol.

An alternative interim restoration

If immediate implant restoration is unsuitable, plan an appropriate independent interim arrangement. Assess how it avoids compromising the surgical site and tissues.

Protected healing with reassessment

When findings change, reconsider the restorative sequence and protection. The existence of a prepared provisional does not oblige the team to connect it.

For immediate anterior single-tooth treatment, the 2023 ITI report discusses provisional contour, polished surfaces, occlusal control and an alternative if the intended pathway cannot be completed. Its scope is the anterior maxilla; it is not a universal complete-arch provisional protocol.[5]

Complete-arch loading requires its own assessment of the reconstruction and support. The 2026 maxillary consensus addresses those decisions in a separate clinical setting.[6]

Revisit complete-arch design and sequencing

04 / Before the definitive restoration

Make the handover explainable.

Use these prompts for a supervised case presentation. They connect clinical findings and restorative verification without assigning a universal loading date, medication regimen or manufacturer-independent test threshold.

  1. 01

    The site and healing course

    Review tissues, wound history, relevant symptoms and any augmentation. Resolve unexpected findings before advancing the restorative plan.

  2. 02

    Support and its assessment

    Record the method, timing and clinical context of stability assessment. Interpret serial findings consistently; do not convert torque into ISQ.

  3. 03

    The provisional arrangement

    State how it is retained, its intended contacts and how the implant and tissues are protected. Review comfort, function and usable cleaning access.

  4. 04

    Restorative readiness

    Confirm tissue conditions, required records and component information. Verify fit and the proposed bite; additional reviews or try-ins may be necessary.

  5. 05

    Baseline and continuing care

    Document the delivered design and clinical baseline. Demonstrate suitable self-care and arrange individual professional review.

05 / Clinical reasoning

Explain which decision the finding supports.

Discuss each scenario before opening the suggested reasoning.

A healing abutment is visible through the gum. Is the implant already loaded?

Not necessarily. A transmucosal healing component is not a provisional crown in occlusion. Describe the surgical configuration and the prosthesis separately; exposure through mucosa alone does not identify the loading protocol.[2][4]

The planned loading date has arrived, but the findings are uncertain. What takes priority?

Reassess the actual site, support and restorative proposal. A timing category does not certify readiness. Explain the reasons for maintaining protection, obtaining further assessment or changing the interim plan in the clinical context.[5][6]

Can insertion torque and ISQ be converted into the same readiness score?

No validated conversion is provided by the cited review. These measurements assess stability differently, and the review found low-certainty evidence for their relationship. Interpret the recorded method and clinical context rather than replacing assessment with one interchangeable score.[3]

06 / Evidence and its limits

Match the evidence to the clinical question.

Biology, measurement studies, surgical healing configurations, site-specific loading recommendations and prevention guidance answer different questions. The original study plates illustrate concepts; no journal figure, histological image or measured stability curve is reproduced.

  1. [1] Biological review / 2017

    Osseointegration of titanium, titanium alloy and zirconia dental implants: current knowledge and open questions

    Bosshardt DD, Chappuis V, Buser D. Periodontology 2000. 73(1):22–40. doi:10.1111/prd.12179.

    Explains bone formation and remodelling at the implant interface, drawing on experimental and clinical knowledge. Biological observations do not establish a patient-specific loading date or a universal stability curve.

  2. [2] ITI consensus terminology / 2018

    Implant Placement and Loading Protocols

    Gallucci GO, Hamilton A, Zhou W, Buser D, Chen ST. 6th ITI Consensus Conference. Prosthodontics and Implant Dentistry.

    The four restoration/loading definitions in the study plate follow this classification. They name protocols; they are not a timetable for completing healing or a promise of definitive teeth.

  3. [3] Systematic review / 2018

    Relationship between implant stability measurements obtained by insertion torque and resonance frequency analysis: A systematic review

    Lages FS, Douglas-de Oliveira DW, Costa FO. Clinical Implant Dentistry and Related Research. 20(1):26–33. doi:10.1111/cid.12565.

    Twelve clinical studies examined the relationship between insertion torque and ISQ. Evidence certainty was low; the measurements should not be treated as interchangeable numerical scales.

  4. [4] Systematic review and meta-analysis / 2018

    Early and late implant failure of submerged versus non-submerged implant healing: A systematic review, meta-analysis and trial sequential analysis

    Troiano G, Lo Russo L, Canullo L, Ciavarella D, Lo Muzio L, Laino L. Journal of Clinical Periodontology. 45(5):613–623. doi:10.1111/jcpe.12890.

    Compares submerged and non-submerged healing in prospective studies without immediate loading. The surgical healing configuration is therefore a different question from whether a provisional prosthesis is loaded.

  5. [5] ITI consensus report / 2023

    Group 5 ITI Consensus Report: Implant placement and loading protocols

    Morton D, Wismeijer D, Chen S, et al. Clinical Oral Implants Research. 34(Suppl 26):349–356. doi:10.1111/clr.14137.

    Includes immediate placement/restoration of single teeth in the anterior maxilla, provisional design and alternatives when the intended protocol cannot be completed. Do not transfer its site-specific recommendations unchanged to complete arches.

  6. [6] Global consensus report / 2026

    Consensus Report of Group 1 of the 1st Global Consensus for Clinical Guidelines for the Rehabilitation of the Edentulous Maxilla: Number of Implants, Timing of Implant Placement and Loading

    Donos N, Ng E, Pannuti CM, et al. Clinical Oral Implants Research. 37(Suppl 30):S28–S48. doi:10.1111/clr.70063.

    A contemporary, maxilla-specific consensus supporting individual assessment of placement and loading. Its scope differs from the anterior single-tooth ITI report and from biological interface research.

  7. [7] EFP S3 clinical practice guideline / 2023

    Prevention and treatment of peri-implant diseases—The EFP S3 level clinical practice guideline

    Herrera D, Berglundh T, Schwarz F, et al. Journal of Clinical Periodontology. 50(Suppl 26):4–76. doi:10.1111/jcpe.13823.

    Connects preventive design, patient self-care, clinical records and continuing professional care. Some preventive recommendations rely on indirect evidence or expert consensus; this is not a universal recall schedule.